SU-E-T-176: Commissiong and Initial Clinical Experience with Dosimetry Check, a Commercial Software for in Vivo Volumetric Dosimetry
2013
Purpose: The aim of this work is to study the differences of reference point doses between the commercial EPID based dosimetry software Dosimetry Check (DC) and TPS to establish an accuracy level of the system, to evaluate its use in clinical routine and to obtain results for the first patients. Methods: We used DC v.3.8 (Math Resolutions), two Varian Clinac iX accelerators equipped with EPID aS1000 and Eclipse v.10.0 with AAA algorithm. Several plans with and without air gap were generated over the phantoms: MP1 Water Tank and Solid Octavius 4D (PTW). 5 head and neck, 3 lung and 4 prostate cases were selected for clinical evaluation. We compared the calculated dose at the isocenter and in …
SU-E-J-69: Evaluation of the Lens Dose On the Cone Beam IGRT Procedures
2014
Purpose: With the establishment of the IGRT as a standard technique, the extra dose that is given to the patients should be taken into account. Furthermore, it has been a recent decrease of the dose threshold in the lens, reduced to 0.5 Gy (ICRP ref 4825-3093-1464 on 21st April, 2011).The purpose of this work was to evaluate the extra dose that the lens is receive due to the Cone-Beam (CBCT) location systems in Head-and-Neck treatments. Methods: The On-Board Imaging (OBI) v 1.5 of the two Varian accelerators, one Clinac iX and one True Beam, were used to obtain the dose that this OBI version give to the lens in the Head-and-Neck location treatments. All CBCT scans were acquired with the Sta…
Helical Tomotherapy® is a safe and feasible technique for total scalp irradiation
2017
Angiosarcoma of the scalp is a rare aggressive tumor that affects elderly patients. Chemoradiation is the treatment of choice for multicentric and extensive disease. The shape of the scalp represents a dosimetric challenge in terms of achieving a homogeneous concave dose distribution with coverage of the entire target volume and an acceptable organs-at-risk sparing. We report a case of an 81-year-old man with a multifocal angiosarcoma of the scalp treated with Helical TomoTherapy® (Accuray Inc., Sunnyvale, CA, USA) intensity modulated radiotherapy. This technique allows precise and daily verifiable coverage of the target keeping the dose to the organs at risk within the constraints.
Bonnes pratiques de radiothérapie guidée par l’image
2015
Image-guided radiotherapy (IGRT) aims to take into account the anatomical variations occurring during the course of radiotherapy, by direct or indirect visualization of the target volume followed by a corrective action. The movements of the target, or at least the set-up errors are corrected by moving the treatment table, corresponding to the simplest and most validated IGRT modality in a standard practice. The deformations of the target volume and organs at risk are however much more common, and unfortunately much more complicated to consider, requiring multiple planning before or during the treatment, corresponding to the adaptive radiotherapy strategies. The planning target volume must b…
Evaluation of lens absorbed dose with Cone Beam IGRT procedures
2015
The purpose of this work is to evaluate the absorbed dose to the eye lenses due to the cone beam computed tomography (CBCT) system used to accurately position the patient during head-and-neck image guided procedures. The on-board imaging (OBI) systems (v.1.5) of Clinac iX and TrueBeam (Varian) accelerators were used to evaluate the imparted dose to the eye lenses and some additional points of the head. All CBCT scans were acquired with the Standard-Dose Head protocol from Varian. Doses were measured using thermoluminescence dosimeters (TLDs) placed in an anthropomorphic phantom. TLDs were calibrated at the beam quality used to reduce their energy dependence. Average dose to the lens due to …
Impact of rectal distension on prostate CBCT-based positioning assessed with 6 degrees-of-freedom couch
2018
International audience; Introduction: Prostate requires a daily correction of its 3-dimensional position in relation with rectal distension. In this study, we sought to determine whether rectal distension with respect to the rectal behavior might have an impact on prostate translations and/or rotations during prostate image guided radiation therapy using a 6 degrees-of-freedom (DOF) couch.Methods and materials: We reviewed the data from 39 patients with localized prostate cancer treated with protracted external radiation therapy using a 6 DOF couch. Before each fraction, a kilovoltage cone beam computed tomography (kV-CBCT) scan was performed. The automatic fusion algorithm was set to fuse …
SU-GG-T-227: Dynamic IMRT Split Beam Technique Verification Using EPID Based Dosimetry
2010
Purpose: On dynamic IMRT plans with Millenium 80 (Varian) fields wider of 15 cm must be splitted. Since the EPIDdosimetry software does not allow to sum splitted subfluences in the same dosimetric portal image they have to be measured separately and compared independently with the subfluences previously calculated by the TPS Eclipse. The purpose of our work is the development of a tool to: 1) analyze the correct match between the two abutted ports for splitted fields. 2) study the effect of gravity and analyze repercussions of possible misalignments and 3) illustrate that the gamma evaluation should be made with the global summed fluence per field instead of with the individual subfluences.…